| 注册
首页|期刊导航|广东水利水电|飞来峡电厂 4#机组桨叶接力器故障原因查找与分析

飞来峡电厂 4#机组桨叶接力器故障原因查找与分析

肖南文

广东水利水电Issue(10):60-63,4.
广东水利水电Issue(10):60-63,4.

飞来峡电厂 4#机组桨叶接力器故障原因查找与分析

Troubleshooting and Analysis of the Blade Relay Device at FeiLaiXia Power Plant 4#Units

肖南文1

作者信息

  • 1. 广东省飞来峡水利枢纽管理处发电厂, 广东清远 511825
  • 折叠

摘要

Abstract

For the phenomenon of governor oil pump pumping frequently in the FeiLaiXia power plant 4# units, the analysis get a conclusion is the blade relay device was broken, and find out the direct reason is the Blade relay cylinder Roulette bolt falled off in open cavity, scraping in the gap between the piston and cylinder, caused cylinder body burst apart, lead to the blade relay closed and open cavity string of oil.the damaged blades relay cylinder and piston got through soldering, laser Molten and surface Lathe Roughing Operation, then, the blade relay device was fitted back, as a result, the phenomenon of oil pump was disappeared, and the 4# units running in good condition now.

关键词

飞来峡电厂/油泵启动频繁/串油

Key words

Feilaixia power station/oil pump start frequently/string of oil

分类

能源科技

引用本文复制引用

肖南文..飞来峡电厂 4#机组桨叶接力器故障原因查找与分析[J].广东水利水电,2015,(10):60-63,4.

广东水利水电

1008-0112

访问量0
|
下载量0