龚维明 龚静雅 张宇

排灌机械工程学报Issue(12):1091-1096,6.
排灌机械工程学报Issue(12):1091-1096,6.DOI:10.3969/j.issn.1674-8530.15.0166

高压电动机定子绕组绝缘薄弱点的有效定位

High voltage motor stator winding insulation vulnerabilities of effective positioning

龚维明 1龚静雅 2张宇1

作者信息

  • 1. 江苏省江都水利工程管理处,江苏 扬州 225200
  • 2. 江苏省鸿源招标代理股份有限公司,江苏 南京 210019
  • 折叠

摘要

Abstract

For partial discharge detection method (no matter online or off-line),it can only be used to determine the discharge capacity of a phase stator winding insulation,which can be used to detect the discharge position and intensity.According to the situation of the field,the noise,electromagnetic in-terference and other interference sources to the motor stator winding test were reduced,the high voltage motor stator winding sound power of the test of the normal situation and internal discharge.were summed up.A large number of field tests were carried out to establish the discharge points of different types and different discharge levels,and to carry out the accuracy of the spectrum information and to verify the location.The combined detection of the sound and the pulse current is used in combination with the pulse current detection,and the different discharge points of the stator winding of high voltage motor are judged by comparing the signal spectrum and the pulse current detection.The insulation con-dition and performance of the main motor windings of the Jiangdu Railway Station are provided by the positioning test of the weak point of the stator winding insulation of high voltage motor.

关键词

高压电动机/绝缘薄弱点/位置探测系统/定位/局部放电检测

Key words

high voltage motor/insulation vulnerabilities/location detection system/positioning/partial discharge detection

分类

农业科技

引用本文复制引用

龚维明,龚静雅,张宇..高压电动机定子绕组绝缘薄弱点的有效定位[J].排灌机械工程学报,2015,(12):1091-1096,6.

基金项目

国家自然科学基金资助项目(51379182);江苏省水利科技基金资助项目 ()

排灌机械工程学报

OA北大核心CSCDCSTPCD

1674-8530

访问量0
|
下载量0
段落导航相关论文