| 注册
首页|期刊导航|理化检验-物理分册|脱沥青油相加热炉对流室炉管泄漏原因分析

脱沥青油相加热炉对流室炉管泄漏原因分析

赵首永 于粉林

理化检验-物理分册Issue(1):50-53,4.
理化检验-物理分册Issue(1):50-53,4.DOI:10.11973/lhjy-wl201601014

脱沥青油相加热炉对流室炉管泄漏原因分析

Leakage Reason Analysis on the Furnace Tube of Convection Chamber of Deasphalting Heating Furnace

赵首永 1于粉林1

作者信息

  • 1. 中国石化洛阳分公司,洛阳 471012
  • 折叠

摘要

Abstract

In one heating furnace of the solvent deasphalting unit,the corrosion and leakage occurred in the furnace tube of H103 convection chamber.By checking the corrosion situation of leakage positions,the leakage reasons were analyzed from the aspects of the sulfur content of heating furnace gas,exhaust temperature,oxygen content of the flue gas,dust blowing situation,wall thickness monitoring of the furnace tube,and so on.The results show that the corrosion of furnace tube was the result of the interaction of dew point corrosion of flue gas and the under-deposit corrosion.In view of corrosion and leakage reasons of the furnace tube,the corresponding improvement measures were proposed to ensure the safe operation after overhaul.

关键词

加热炉/对流室炉管/露点腐蚀

Key words

heating furnace/furnace tube of convection chamber/dew point corrosion

分类

能源科技

引用本文复制引用

赵首永,于粉林..脱沥青油相加热炉对流室炉管泄漏原因分析[J].理化检验-物理分册,2016,(1):50-53,4.