现代雷达Issue(2):70-74,94,6.DOI:10.16592/j.cnki.1004-7859.2016.02.016
脉冲负载作用下衡量电压畸变率的方法研究
A Study on the Method Measuring the Distortion Rate of Voltage under the Action of Pulse Load
韩航星 1严豪杰 1徐晔 1王金全 1胡亚超2
作者信息
- 1. 解放军理工大学国防工程学院,南京210007
- 2. 解放军91362部队,浙江舟山316200
- 折叠
摘要
Abstract
The power quality of the independent low-power system is closely related to the load characteristics.In the system that the diesel generator set operates alone with pulse load, the output voltage of the diesel generator set is distorted.When the load changes suddenly, the voltage frequency fluctuates greatly, thus it is difficult to obtain the fundamental frequency and extract each harmonic effectively.In this case, it is useless to measure the distortion rate of voltage using the total harmonic distortion ( THDv) .Hence, a method measuring the distortion rate of voltage under the action of the pulse load, namely distortion rate of voltage ( DRV) is presented.By testing the experiment system of the diesel generator set working with the pulse load, and compa-ring THDV with DRV in different operational modes, the method proposed in this paper is verified to be reasonable.At this base, the influence law of pulse load working mode and the generator output power to the DRV is obtained.关键词
脉冲负载/电压畸变率/频率波动Key words
pulse load/distortion rate of voltage/frequency fluctuation分类
信息技术与安全科学引用本文复制引用