Based on the daily variation of geomagnetic data recorded by fluxgate magnetometer GM4-2 at Hongshan geomagnetic observatory,this paper propo-ses a method for eliminating instrument orientation error,namely the correction method for magnetic axis zero drift S 0 of D element.First,based on the mea-surement theory of magnetic axis zero drift S 0 ,a rotation platform without magnetism has been trial-produced to measure the S0 ,which is about 1 024.7 nT for the GM4-2.Then,we correct the error of S 0 value in reorientation.Finally, the S 0 value is applied to both theoretical daily variation and daily variation recorded by the instrument after orientation.The results show that the magne-tic axis zero drift S 0 of D element is the main factor for the orientation error. The daily variation recorded by the instrument after orientation are consistent with the theoretical daily variation,thus eliminating the daily variation distor-tion caused by the orientation error,and reflecting the geomagnetic filed varia-tion more realistically.

关键词

磁通门磁力仪/GM4-2 定向/零场漂移 S0/无磁旋转平台

Key words

fluxgate magnetometer GM4-2/orientation/the magnetic axis zero drift S 0/rotation platform without magnetism

分类

天文与地球科学

引用本文复制引用

胡秀娟,李西京,王静,李细顺,畅国平,王秀敏,宋昭,罗娜,解真..仪器定向误差对地磁日变化记录准确度的影响研究[J].地震学报,2016,(1):130-137,8.

基金项目

河北省地震局三结合课题(DZ20150424093)和中国地震局行业标准(054219)共同资助. ()

地震学报

OA北大核心CSCDCSTPCD

0253-3782

访问量0
|
下载量0
段落导航相关论文