强激光与粒子束2016,Vol.28Issue(4):84-89,6.DOI:10.11884/HPLPB201628.045004
LTD模块串联装置中部分模块不工作时的输出性能
Performance of 10-stage LTD generator with some malfunctioning stages
摘要
Abstract
The performance of the 10-stage LTD generator is investigated in experiments with some stages uncharged or un-triggered.The result shows that both the current and the voltage decrease by almost 10%,20% and 30%,the pulse rise-time in-creases by 10,22 and 32 ns and the pulse width increases by 13,23 and 48 ns,for 1,2 and 3 malfunctioning stages respectively. Compared with the LTD generator in good condition,the equivalent circuit simulation of the LTD generator working abnormally demonstrates that the variation trends of the current and the voltage in the load agree well with the experimental results.In addi-tion,the induced voltage on the switch in the malfunction stage is simulated and analyzed.关键词
直线型变压器驱动源/故障/电流/电压/电路模拟Key words
fast linear transformer driver/malfunction/current/voltage/electric circuit simulation分类
信息技术与安全科学引用本文复制引用
陈林,蒋吉昊,邹文康,郭帆,王勐,赵越,刘瑜,王杰,张元军..LTD模块串联装置中部分模块不工作时的输出性能[J].强激光与粒子束,2016,28(4):84-89,6.基金项目
国家自然科学基金项目(51407171) (51407171)