强激光与粒子束2016,Vol.28Issue(4):184-189,6.DOI:10.11884/HPLPB201628.045106
滚边法测量高能X射线源焦斑大小
High energy X-ray spot size measurement with rollbar
摘要
Abstract
The X-ray spot size is a critical parameter for flash radiography facility which degrades resolution in the flash radi-ography.It is difficult to measure the X-ray spot size in the condition of intense radiation and its penetrability.This paper de-scribes a rollbar used to measure the X-ray focal spot size.The edge spread function(ESF),line spread function(LSF)and modu-lation transfer function(MTF)of the X-ray spot are obtained from the rollbar image data,and the X-ray spot size is determined by the MTF.In the experiment of Dragon-Ⅱ linear induction accelerator downstream and target,the X-ray spot size is measured and the results are analyzed.关键词
高能X射线/焦斑大小/调制传递函数/滚边装置Key words
high energy X-ray/spot size/modulation transfer function/rollbar分类
信息技术与安全科学引用本文复制引用
李勤,王毅,李成刚,李洪,祁双喜,刘云龙,程晋明,李天涛,龙全红..滚边法测量高能X射线源焦斑大小[J].强激光与粒子束,2016,28(4):184-189,6.基金项目
国防科技专项研究基金项目 ()