During the ultrasonic cutting of the cellular composite,the failure of the match between ultrasonic and impedance of transducer leads to the reduce of the quality and efficiency of machining of materials,and even damages ultrasound equipment. The key to solve this problem is that realize the dynamic matching by detecting impedance angle on line and in real time. Based on the relevant principles of orthogonal,a new method to detect the impedance angle is proposed,which is independent with whether to synchronize with the sampling. And this way realizes the on-line detection of impedance angle by using the microprocessors and sensor measuring circuit. Simulation and experiments show that the method is suitable for synchronous and asynchronous sampling of ultrasound signal frequency and lays the foundation for the realization of dynamic matching. Besides,this method needs the small amount of calculation,is real-time and has high accuracy,and specially after the improvements,its error closes to 0. 0551°.关键词
计算学/超声换能器/阻抗匹配/阻抗角/正交相关原理Key words
metrology/ultrasound transducer/impedance matching/impedance angle/orthogonal related principle分类
通用工业技术引用本文复制引用
纪华伟,李旭龙,胡小平..改进的正交相关超声换能器阻抗角测量新方法[J].计量学报,2016,(1):79-83,5.基金项目
国家自然科学基金(51475130);国防科工局重大专项 ()