交通信息与安全Issue(1):96-102,7.DOI:10.3963/j.issn 1674-4861.2016.01.001
基于 FTA 失效评估的电脉冲除冰电源 E-bayes 可靠性分析
An E-bayes Reliability Analysis of the EIDI Power Supply Based on FTA Failure Assessment
刘琳 1葛红娟 1陈鹏1
作者信息
- 1. 南京航空航天大学民航学院 南京 211106
- 折叠
摘要
Abstract
An E-bayes reliability analysis method is proposed based on FTA Failure Assessment to evaluate the reli-ability of airborne equipment in case of zero-failure data.The failure rate of electro-impulse de-icing (EIDI)power supply is calculated by FTA analysis,and incorporated to the E-bayes estimation for computing the censored time for the k+1 fix-time censored test.Then the E-bayes method is used to estimate the average life of EIDI power supply.The robustness of the average life estimation of power supply is studied via a comparison of traditional E-bayes method,synthetic expec-ted-bayes method and E-bayes reliability analysis method,based on FTA failure assessment.The results indicate that this E-bayes reliability analysis method based on FTA failure assessment is robust,feasible and convenient to be applied in en-gineering in the case of zero-failure data.关键词
航空安全/可靠性评估/无失效数据/E-bayes 估计/故障树分析/稳健性Key words
aviation safety/reliability assessment/zero-failure data/E-bayes estimation/FTA/robustness分类
航空航天引用本文复制引用
刘琳,葛红娟,陈鹏..基于 FTA 失效评估的电脉冲除冰电源 E-bayes 可靠性分析[J].交通信息与安全,2016,(1):96-102,7.