浙江电力Issue(2):60-62,67,4.
TP347H过热器管爆管原因分析
Cause Analysis on Tube Burst of TP347H Superheater
魏星 1唐丽英2
作者信息
- 1. 神华福建能源有限责任公司,福州 350004
- 2. 西安热工研究院有限责任公司,西安 710032
- 折叠
摘要
Abstract
Tube burst causes of secondary superheater TP347H in supercritical generating units are analyzed through macrographic examination and inspection on metallographic structure, fracture appearance and me-chanical property. The result shows that the causes of the tube burst are microcracks and local segregation de-fects in the material. It is advised that the inspection on boiler tubes should be strengthened and the tubes with cracks should be replaced in time.关键词
TP347H/爆管/显微裂纹/偏析Key words
TP347H/burst tube/microcrack/segregation分类
能源科技引用本文复制引用
魏星,唐丽英..TP347H过热器管爆管原因分析[J].浙江电力,2016,(2):60-62,67,4.