广东电力2016,Vol.29Issue(1):65-69,5.DOI:10.3969/j.issn.1007-290X.2016.01.013
基于改进分类用户单位停电损失函数法的电力用户缺供电损失分析
Analysis on Insufficient Power Supply Loss of Electricity Customers Based on Improved Sector Custom Unit Damage Function Method
徐涛 1李明贞 2刘毅刚 1李秋芳 2徐研1
作者信息
- 1. 广州供电局有限公司,广东 广州 510620
- 2. 武汉大学 电气工程学院,湖北 武汉 430072
- 折叠
摘要
Abstract
In order to effectively estimate insufficient power supply loss of customers of city power grids,this paper proposes a kind of calculation model for insufficient power supply loss by analyzing influencing factors on insufficient power supply loss and improving sector customer unit damage function (SCUDF)method.Based on insufficient power supply loss data of traditional customers and macroscopical statistic data of secondary and tertiary industries in Guangzhou area,this calculation model for insufficient power supply loss is used to calculate insufficient power supply loss function.Taking some line cable fault as an example,the calculation model,SCUDF method and GNP estimation method is respectively used for working out insufficient power supply loss of target customers.Results indicate that on the premise of satisfying the goal hypothesis,cal-culation result of the model is more accurate which is close to that of SCUDF method,while the result may be lack of accu-racy by using GNP estimation method.关键词
缺供电损失模型/用户缺供电损失/可靠性评估/用户分类Key words
insufficient power supply loss model/insufficient power supply loss of customer/reliability evaluation/customer classification分类
信息技术与安全科学引用本文复制引用
徐涛,李明贞,刘毅刚,李秋芳,徐研..基于改进分类用户单位停电损失函数法的电力用户缺供电损失分析[J].广东电力,2016,29(1):65-69,5.