摘要
Abstract
Through the capacity expansion of No.1 generating-unit in Huaan hydropower plant, the flow passage wear, the unreliable leakage of main-shaft sealing, the leakage of main-spindle center air admission inlet and other prob-lems were solved. Combination appeared problems when No.1 generating-unit of Huaan Hydropower Station was technically transformed and corresponding solutions, key technologies and matters needing attention of hydropower generator units transformation were formulated, which will provide the reference for the future related projects.关键词
技术改造/主轴密封/主轴中心补气/调速器Key words
technical transformation/main-shaft seal/main-spindle center air admission/speed governor分类