Abstract
In theprocess ofPV power plant test, to solve the problem of excessive deviation between the parallel mis-matchtest result andthe actual situation, due to the measurement error, this paper proposes an analysis method based on I-V characteristicssuperposition, whichsubstantially improves the accuracy of the analysis. The method above makes it possibleto analyze parallel mismatchonline. And then an effective method of fault identification and parallel mismatch optimization is-proposed, which is helpful to improving the management level of thePV power plant.关键词
光伏检测/并联失配/I-V特性/在线分析Key words
PV power plant test/parallel mismatch/I-V characteristics/online analysis分类