Based on the leading power factor test guidelines of synchronous generator, the calculation method of leading power factor depth limit constrained by generator power angle was presented, and the impaction of system reactance on system static stability with power angle limited was studied. Meanwhile, the values of terminal voltage and stator current were checked and the modification of leading power factor depth limit was given if these values were over-limit. Taking 1# generator of Ruijin thermal power plant for example, the PQ curves of leading power factor depth limit changing with active power were showed under different system voltage conditions. The results considering constraints of leading power factor test could provide references for experimenters to control leading power factor depth so as to ensure the safety and stability of generator in the tests.关键词
隐极同步发电机/进相试验/静态稳定/进相深度限值Key words
non-salient synchronous generator/leading power factor test/static stability/leading power factor depth limit分类
信息技术与安全科学引用本文复制引用
陈波,周宁,舒展,苏永春..进相试验约束条件下隐极同步发电机进相深度限值分析[J].电机与控制应用,2016,43(2):30-35,6.