| 注册
首页|期刊导航|中国组织工程研究|两种新型通用型处理剂对氧化锆黏结强度的影响

两种新型通用型处理剂对氧化锆黏结强度的影响

杨慧 徐雄均 陈强 陈霞云 江浩顺 孙文娟 刁惠波

中国组织工程研究2016,Vol.20Issue(8):1153-1158,6.
中国组织工程研究2016,Vol.20Issue(8):1153-1158,6.DOI:10.3969/j.issn.2095-4344.2016.08.013

两种新型通用型处理剂对氧化锆黏结强度的影响

Effects of two new multipurpose treatment agents on the bond strength of zirconia

杨慧 1徐雄均 1陈强 1陈霞云 1江浩顺 1孙文娟 1刁惠波1

作者信息

  • 1. 中山大学附属第三医院,广东省广州市 510630
  • 折叠

摘要

Abstract

BACKGROUND: BACKGROUND: Studies have found that surface treatment agents containing 10-methacryloyloxy decyl dihydrogen phosphate may be chemical y bonded to the oxide on the surface of zirconia, thereby notably improving the bonding performance of zirconia. OBJECTIVE: To study the effects of Mondbond N and Single bond Universal Adhesive on microtensile bond strength between zirconia and composite resin. METHODS: Sixty pieces of zirconia were randomized into three groups: in group 1, conventional Bis-GMA resin cement was used to bond zironia and composite resin; in group 2, conventional Bis-GMA resin cement was used to bond zironia and composite resin fol owing Mondbond N treatment; in group 3, conventional Bis-GMA resin cement was used to bond zironia and composite resin fol owing surface treatment with Single Bond Universal Adhesive containing 10-methacryloyloxy decyl dihydrogen phosphate. Microtensile bond strength and microstructure on the bonding interface were compared among three groups. RESULTS AND CONCLUSION: (1) Microtensile bond strength was significantly higher in the groups 2, 3 than group 1 (P < 0.05), and there was no difference between the two former groups. (2) Scanning electron microscope observation of the bonding interface: before microtensile test, there were more fissures on the bonding interface of group 1; in the group 2, there were a few fissures on the bonding interface that was relatively even; in the group 3, the bonding interface was smooth and continuous with few fissures. After microtensile, cohesive failure and bonding interface failure were mainly seen in the three groups, but there was no simple interface failure in the groups 2 and 3. These findings indicate that Monobond N and Single Bond Universal Adhesive can both improve the bonding strength of zirconia with composite resin.

关键词

生物材料/口腔生物材料/氧化锆/表面处理/微拉伸黏结强度/10-甲基丙烯酰氧癸基磷酸酯

分类

医药卫生

引用本文复制引用

杨慧,徐雄均,陈强,陈霞云,江浩顺,孙文娟,刁惠波..两种新型通用型处理剂对氧化锆黏结强度的影响[J].中国组织工程研究,2016,20(8):1153-1158,6.

基金项目

广东省科技计划项目(2010B031100011)Funding:the Scientific Research Project of Guangdong Province, No.2010B031100011 (2010B031100011)

中国组织工程研究

OA北大核心CSTPCD

2095-4344

访问量0
|
下载量0
段落导航相关论文