Abstract
Objective To improve the safety and accuracy of high-frequency electric knife.Methods Electrical safety test was conducted by using ES601 and HF-400 high-frequency electric knife detector in strict accordance with testing standards to detect unqualified high-frequency electric knife and analyzed the factors that contribute to the unqualiifed situation.Results Among the factors that contribute to the disqualification, the main cause of the malfunction of the high frequency electric knife is the unqualiifed high frequency.Conclusion The routine maintenance of equipment needs to be strengthened. Different measures are needed to be taken for different situations to improve the safety and passing rate of the equipment.关键词
高频电刀/高频电刀检测仪/高频电流检测仪/漏电流/质量控制Key words
high-frequency electric knife/high-frequency electric knife detector/high-frequency electrical current detector/leakage current/quality control分类
机械工程引用本文复制引用