| 注册
首页|期刊导航|中国医疗设备|高频电刀的质量控制结果分析

高频电刀的质量控制结果分析

左宏 李朝晖

中国医疗设备2016,Vol.31Issue(3):134-135,101,3.
中国医疗设备2016,Vol.31Issue(3):134-135,101,3.DOI:10.3969/j.issn.1674-1633.2016.03.037

高频电刀的质量控制结果分析

Analysis of the Results of Quality Control of High-frequency Electric Knife

左宏 1李朝晖1

作者信息

  • 1. 解放军251医院医学工程科,河北张家口 075000
  • 折叠

摘要

Abstract

Objective To improve the safety and accuracy of high-frequency electric knife.Methods Electrical safety test was conducted by using ES601 and HF-400 high-frequency electric knife detector in strict accordance with testing standards to detect unqualified high-frequency electric knife and analyzed the factors that contribute to the unqualiifed situation.Results Among the factors that contribute to the disqualification, the main cause of the malfunction of the high frequency electric knife is the unqualiifed high frequency.Conclusion The routine maintenance of equipment needs to be strengthened. Different measures are needed to be taken for different situations to improve the safety and passing rate of the equipment.

关键词

高频电刀/高频电刀检测仪/高频电流检测仪/漏电流/质量控制

Key words

high-frequency electric knife/high-frequency electric knife detector/high-frequency electrical current detector/leakage current/quality control

分类

机械工程

引用本文复制引用

左宏,李朝晖..高频电刀的质量控制结果分析[J].中国医疗设备,2016,31(3):134-135,101,3.