电力系统保护与控制2016,Vol.44Issue(7):128-133,6.DOI:10.7667/PSPC150910
基于IEC 60870-5-104规约扩展的配电终端自描述功能实现方法研究
Research method for implementation of the self-describing function of distribution terminals based on the extended IEC 60870-5-104 protocol
摘要
Abstract
In order to make the data lacking in descriptions enjoy self-describing information, the IEC 61850 is applied to the modeling of distribution terminal. The protocol IEC 60870-5-104 don’t support the transmission of the self-describing information, the advantages and disadvantages of several model file mapping methods are analyzed and the extension to 104 protocol is put forward to solve the problem. The message used to transfer self-description information of devices is designed through referring to the message format of 104 protocol, which can realize the self-describing function of the distribution terminal. At the same time, a terminal description information update mechanism is proposed based on the extended 104 protocol. The feasibility of the scheme is confirmed by the test on the distribution automation system of NARI.关键词
IEC 61850/IEC 60870-5-104/配电终端/信息模型/协议扩展/自描述Key words
IEC 61850/IEC 60870-5-104/distribution terminal/information model/protocol extensions/self-description引用本文复制引用
徐迅,梅军,钱超,郑建勇,王勇,稽文路,张明..基于IEC 60870-5-104规约扩展的配电终端自描述功能实现方法研究[J].电力系统保护与控制,2016,44(7):128-133,6.基金项目
国家电网2016年科技项目“具备配电线路自组网能力的智能配电监控终端技术研究” ()