摘要
Abstract
Operation problems of coal-fired units SCR denitrification were analyzed, discussed the flue gas flow field uneven, NH3/ NOxmole ratio of the uneven distribution, air pre - heater fouling serious and denitration CEMS poor representation of causes and correspondingmeasures. It was found through the inlet flue denitration diversion and rectification, ammonia injection optimization and strict control of ammonia eacape rate, significant-ly improved operating results SCR denitrification system and improve the efficiency of denitrification, research results significantly promote the action of energy saving and emission reduction in power industry.关键词
氮氧化物/SCR脱硝/喷氨优化/氨逃逸/CEMSKey words
nitrogen oxides/SCR denitrification/ammonia injection optimization/ammonia escape/CEMS分类
资源环境引用本文复制引用
马大卫,查智明,黄齐顺,许勇毅..安徽省燃煤机组SCR脱硝装置运行情况及分析[J].电力科技与环保,2016,32(2):22-25,4.