Abstract
Because of the diversity between environmental quality standard for noise and cooling tower′s national standard in some susceptible area , the second category of acoustic environment noise will be over standard easi-ly.This paper , taking cooling tower noise reduction scheme in a metro station of GuangZhou Metro Line 6 and Guangfo Line as an example , studies the design and placement of cooling tower , the addition of noise reduction en-closure , noise silencing governance , etc.Furthermore , combined with the treatment effect , it put forward sugges-tions for the control of the cooling tower noise elimination .关键词
冷却塔/性能/消声降噪Key words
Cooling tower/Performance/Noise elimination and reduction分类
建筑与水利引用本文复制引用