电力系统自动化2016,Vol.40Issue(8):103-107,5.DOI:10.7500/AEPS20150804008
LCL 型非接触电能传输系统电路特性分析及参数配置方法
Circuit Characteristic Analysis and Parameter Configuration Method of LCL Type Contactless Power Transfer System
摘要
Abstract
The two-port circuit theory is introduced to a contactless power transfer(CPT) system,by means of which an LCL type CPT system is modeled and analyzed.After that,the relationship between the input and output voltage is found.At the same time,the new model of the coupling mechanism is given,which makes the analysis very simple.Based on this,a new parameter configuration method of the whole system is given,and the output voltage,power and efficiency characteristics are analyzed.In order to prove the superiority of this method,the output power formula of an SS type CPT system is deduced and compared.The results show that the proposed method has a much higher output voltage and power as proved by simulation and experimental results.关键词
非接触电能传输(CPT)/二端口理论/输入输出关系/电路特性/参数配置Key words
contactless power transfer (CPT)/two-port theory/input-output relationship/circuit characteristics/parameter configuration引用本文复制引用
孙跃,张欢,唐春森,陶维,马浚豪..LCL 型非接触电能传输系统电路特性分析及参数配置方法[J].电力系统自动化,2016,40(8):103-107,5.基金项目
国家高技术研究发展计划(863计划)资助项目(2015AA016201) (863计划)
国家自然科学基金资助项目(51277192) (51277192)
重庆市基础与前沿计划一般项目(cstc2013jcyA0235)。This work is supported by National High Technology Research and Development Program of China (863 Program)(No.2015AA016201) and National Natural Science Foundation of China(No.51277192) (cstc2013jcyA0235)