| 注册
首页|期刊导航|电子器件|基于TDC-GP2的高精度超声波流量计的设计

基于TDC-GP2的高精度超声波流量计的设计

杨兵 崔永俊

电子器件2016,Vol.39Issue(2):447-452,6.
电子器件2016,Vol.39Issue(2):447-452,6.DOI:10.3969/j.issn.1005-9490.2016.02.040

基于TDC-GP2的高精度超声波流量计的设计

Design of High Precision Ultrasonic Flowmeter Based on TDC-GP2

杨兵 1崔永俊2

作者信息

  • 1. 中北大学电子测试技术国家重点实验室,太原030051
  • 2. 中北大学仪器科学与动态测试教育部重点实验室,太原030051
  • 折叠

摘要

Abstract

Based on high precision and reliability of the design idea and in view of the traditional ultrasonic flowme⁃ters the accuracy is not high and the circuit is complicated and the pipeline requires a modification. A design of flowmeter system is proposed based on FPGA and TDC-GP2 high precision time measurement chip. Using FPGA as the core of logic control module, and the principle of time difference method of ultrasonic flow meter, TDC-GP 2 was made to achieve the precise measurement of time difference,the upload data were sent through the serial port to the host computer for data processing and results display. The results show that the accuracy and reliability of the sys⁃tem meet the requirements of the system.

关键词

超声波流量计/时差法/高精度时间测量/TDC-GP2/上位机

Key words

ultrasonic flowmeter/transit-time difference method/TDC-GP2/PC

分类

信息技术与安全科学

引用本文复制引用

杨兵,崔永俊..基于TDC-GP2的高精度超声波流量计的设计[J].电子器件,2016,39(2):447-452,6.

基金项目

国家自然科学基金项目 ()

电子器件

OA北大核心CSTPCD

1005-9490

访问量0
|
下载量0
段落导航相关论文