红外技术2016,Vol.38Issue(3):260-265,6.
基于红外热像仪的温压弹爆炸温度场测试
Explosive Temperature Field Test of the Thermobaric Bomb Based on the Infrared Thermal Imager
摘要
Abstract
The complex field environment has greatly affected the measurement accuracy of the explosion temperature field by the infrared thermal imager. In this paper, the factors affecting the precision of temperature measurement are analyzed from the theoretical point of view, and the relevant improving measures are put forward. In the thermobaric bomb explosion test field, the infrared thermal imager is calibrated by field standard black body. The explosion processes of the temperature and pressure bomb are collected accurately and the relevant data are extracted. The experimental data is processed via MATLAB, and then the temperature field distribution of the explosion fireball surface is obtained: the maximum temperature of the explosion fireball surface is 2881℃;the temperature field duration is 1300ms at 1000℃ and above; the maximum distribution range of the temperature filed is12.61m at 1000℃ and above. Moreover, the CCD high speed camera is set up to carry out the visible light band. The results show that the test data have high accuracy and reliability.关键词
红外热像仪/测温精度/温压弹/温度场分布Key words
infrared thermal imager/temperature measurement accuracy/thermobaric bomb/temperature field distribution分类
信息技术与安全科学引用本文复制引用
田培培,张猛,王高,李仰军,武京治..基于红外热像仪的温压弹爆炸温度场测试[J].红外技术,2016,38(3):260-265,6.基金项目
国家青年基金(11304289),山西省回国留学人员科研资助项目(2014-054,2015-076). (11304289)