| 注册
首页|期刊导航|中国医疗设备|基于肾动态定量分析中肾脏ROI的自动勾画研究

基于肾动态定量分析中肾脏ROI的自动勾画研究

田书畅 徐磊 蒋红兵

中国医疗设备2016,Vol.31Issue(2):44-47,4.
中国医疗设备2016,Vol.31Issue(2):44-47,4.DOI:10.3969/j.issn.1674-1633.2016.02.010

基于肾动态定量分析中肾脏ROI的自动勾画研究

A Research on the Automatic ROI Delineate Method of Renal Imaging Based on Morphological Reconstruction and Otsu Thresholding Segmentation

田书畅 1徐磊 1蒋红兵1

作者信息

  • 1. 南京医科大学附属南京医院 医疗设备处,江苏南京 210006
  • 折叠

摘要

Abstract

Objective To investigate the automatic approach to acquire the single photon emission computed tomography (SPECT) function images of kidney based on morphological reconstruction and Otsu thresholding segmentation.Methods First, we elevated the contrast ratio of the SPECT images for preprocessing. Second, we conducted morphological reconstruction, which could sharpen the edge of kidneys. Then we proceeded to identify the kidney by Otsu thresholding segmentation. Lastly, we got the boundary to achieve the segmentation to realize the automatic region-of-interest (ROI) delineation of the kidneys.Results The automatic ROI delineate method produces better reproducibility, consistency, and accuracy in renal imaging compared with manual method to delineate the kidney.Conclusion The mentioned morphological reconstruction and Otsu thresholding method have great robustness. This procedure can obtain a more rapid, accurate and stable calculation of the glomerular ifltration rate, which makes it signiifcant for clinical application.

关键词

图像分割/肾小球滤过率/形态学重建/最大类间方差法

Key words

image segmentation/glomerular filtration rate/morphological reconstruction/Otsu thresholding

分类

信息技术与安全科学

引用本文复制引用

田书畅,徐磊,蒋红兵..基于肾动态定量分析中肾脏ROI的自动勾画研究[J].中国医疗设备,2016,31(2):44-47,4.

基金项目

南京市医学发展基金“青年工程”人才培养专项经费资助项目(QRX11033)。 ()

中国医疗设备

OACSTPCD

1674-1633

访问量0
|
下载量0
段落导航相关论文