Abstract
Objective This study aimed to investigate the application of the self-produced steam in the sterilization area of Central Sterile Supply Department, and to explore whether the self-produced steam could contribute to the better implementation of the 24 hours sterilization system as well as to the enhancement of the ability to provide apparatuses in urgent need.Methods The original centralized supply was replaced by the self-produced steam in sterilization steam supply mode.Results The self-produced steam had more advantages over the centralized supply in the system management, equipment management, supply time, and so on. The steam-sterilized water was in full compliance with the standard of water. The application of the self-produced steam increased the qualification rate of sterilization, ensured the qualiifcation rate of BD test and batch, and enhanced the security ability. The comparison of the data of two groups indicated that there were signiifcant differences (P<0.05), which was statistically important.Conclusion The self-produced steam not only can improve the steam quality and the sterilization effect, but also can enhance the ability to provide material supply in our department.关键词
蒸汽发生器/消毒供应中心/压力蒸汽灭菌/灭菌用水Key words
steam generator/central sterile supply department/pressure steam sterilization/water for sterilization分类
医药卫生引用本文复制引用
庹琨明,赵卫萍,孟玲,杨涛,李环..蒸汽发生器在消毒供应中心的应用实践[J].中国医疗设备,2016,31(2):135-137,3.