流体机械2016,Vol.44Issue(3):70-75,6.DOI:10.3969/j.issn.1005-0329.2016.03.016
不同真空度下除湿溶液再生性能的试验研究
Experimental Study on Performance of Desiccant-Solution Regeneration in Different Vacuum Degree
韩雨松 1邹同华 1邓赛峰1
作者信息
- 1. 天津商业大学 天津市制冷技术重点实验室,天津 300134
- 折叠
摘要
Abstract
Regeneration in different vacuum degree was carried out using lithium chloride water solution.Influence of each fac-tor on performance of regeneration was studied adopting average moisture removal rate as the evaluation index.Correlations of the parameters were fitted based on the experimental results.The tests were conducted with temperature of heat source 64 ~76℃,ini-tial temperature of solution 45 ~60℃,concentration of solution 28% ~34%,pressure of regenerate process 4 ~10kPa and tem-perature of cold water 13 ~19℃,respectively.Results show that ,temperature of heat source and pressure of regeneration have significant influence on regeneration performance.The temperature of cold water has a weak influence on average moisture removal rate.关键词
真空度/溶液再生/平均再生量Key words
vacuum degree/solution regeneration/average moisture removal rate分类
机械制造引用本文复制引用
韩雨松,邹同华,邓赛峰..不同真空度下除湿溶液再生性能的试验研究[J].流体机械,2016,44(3):70-75,6.