Objective:To observe the influence of replacement frequency of ventilator pipe on pipe bacterial colo-nization in elderly patients with mechanical ventilation.Methods:A total of 64 cases of elderly patients with me-chanical ventilation were selected in our hospital,and were randomly divided into 14 d group and 28 d group by using the lottery method,and then to compare the respiratory secretions bacterial colonization conditions and the incidence of VAP of different parts of ventilator pipes and different mechanical ventilation time between both groups.Results:There was no statistically significant difference in respiratory tract secretions bacterial coloniza-tion and the incidence of VAP in different parts of ventilator pipes and different mechanical ventilation time be-tween two groups (P >0.05).Conclusion:It was also safe to replace a pipeline for interval 28 days in the elderly patients with long term mechanical ventilation by using a disposable closed double heating ventilator wet pipe system.关键词
呼吸机管道/细菌定植/机械通气/呼吸机相关性肺炎/老年病人Key words
ventilator pipe/bacterial colonization/mechanical ventilation/ventilator associated pneumonia/elder-ly patients分类
医药卫生引用本文复制引用
谢银均,蓝惠兰,廖游玩,梁慧梅,容华娟,梁秀娜..呼吸机管道更换频率对老年机械通气病人管道细菌定植的影响[J].护理研究,2016,30(12):1442-1444,3.基金项目