中国电机工程学报2016,Vol.36Issue(7):1801-1807,7.DOI:10.13334/j.0258-8013.pcsee.2016.07.005
云广特高压直流孤岛运行方式下单极闭锁故障分析
Mono-polar Blocking Fault Analysis of Yunnan-Guangdong UHVDC System Islanding Operation
洪潮1
作者信息
- 1. 南方电网科学研究院,广东省广州市 510080
- 折叠
摘要
Abstract
To be used as a normal operation mode, islanding operation at the sending terminal of Yunnan- Guangdong ultra high voltage direct current (UHVDC) transmission system should be able to withstand the impact of various typical faults which can occur during long-time operation. The DC system mono-polar blocking fault is one of the serious faults that the islanding operation must be able to bear. Based on the islanding operation on-site commissioning tests, the testing results of mono-polar blocking fault under the rated DC power operation were analyzed. Using accurate electromagnetic transient simulations of the islanding operation system, the influence of PSS reactive power inverse-regulation of generation units on fault recovery characteristic after the mono-polar blocking were analyzed. The adjustment of power system stabilizer (PSS) output limitations for improving the fault recovery characteristic was evaluated. The analysis provides a technical support for the real system operation using islanding operation modes.关键词
特高压直流输电/孤岛运行/单极闭锁/现场调试/仿真分析/电力系统稳定器Key words
ultra high voltage direct current (UHVDC) transmission/islanding operation/mono-polar blocking/on-site commissioning/simulation analysis/power system stabilizer (PSS)分类
信息技术与安全科学引用本文复制引用
洪潮..云广特高压直流孤岛运行方式下单极闭锁故障分析[J].中国电机工程学报,2016,36(7):1801-1807,7.