摘要

Abstract

In order to improve the performance parameters of domestic short circuit generators,we took a foreign short circuit generator as test power source,established a short circuit breaking and making test system on the basis of direct test method,and put forward a new technical scheme.Simulation results show that the scheme can meet the technical need and the testing criteria of the comprehensive mine electrical laboratory.The scheme provides a solving idea of constructing system for large capacity breaking test.

关键词

短路/开断与关合/发电机/高电压/大电流/试验标准

Key words

short circuit/breaking and making/generator/high voltage/strong current/testing criterion

分类

信息技术与安全科学

引用本文复制引用

陈钊..矿用高压开关电器短路开断与关合试验电源[J].重庆大学学报,2016,39(2):58-63,106,7.

基金项目

矿用新装备新材料安全准入分析验证中心实验室建设项目(2014744)。Supported by Safety Access Approval and Certification Center Laboratory Project of Mining New Equipment, New Materials NDRC Investment(2014744). ()