广东电力2016,Vol.29Issue(4):16-21,6.DOI:10.3969/j.issn.1007-290X.2016.04.003
广东省首台超洁净排放燃煤机组现场测试分析
Analysis on the Test for First Set of Ultra-clean Emission Coal-fired Unit in Guangdong Province
摘要
Abstract
Performance tests on flue gas desulfurization (FGD)system,wet electrostatic precipitator (WESP)system and se-lective catalytic reduction (SCR)system of No.1 unit of Guangzhou Huarun thermal power limited company after its ultra-clean emission transform are conducted ,test method for each system is introduced and test data is analyzed.It is concluded that desulfurization efficiency of the FGD system is above 99%,SO2 emission load of the chimney is below 35 mg/m3 ,de-dusting efficiency of WESP system is 89.09%,dust emission load of the chimney is below 5 mg/m3 ,denitrification rate of the SCR system reaches above 90% and NOx emission load is below 50 mg/m3 .Each system can satisfy requirement for ul-tra-clean emission.关键词
超洁净排放/性能考核试验/烟气脱硫/湿式静电除尘器/选择性催化还原Key words
ultra-clean emission/performance test/flue gas desulfurization (FGD)/wet electrostatic precipitator (WESP)/selective catalytic reduction (SCR)分类
资源环境引用本文复制引用
李德波,曾庭华,廖永进,刘亚明,冯永新,余岳溪..广东省首台超洁净排放燃煤机组现场测试分析[J].广东电力,2016,29(4):16-21,6.基金项目
国家自然科学基金资助项目(51376161)。 (51376161)