可仿真任意工况的MMC等值电磁暂态仿真模型与平均值模型
Equivalent Electromagnetic Model and Averaged Value Model of MMC for Operating Condition Simulation
蒋霖 1周诗嘉 2李子寿 1向往 2胡济洲 1程杰 3劲宇2
作者信息
- 1. 国网湖北省电力公司,武汉430077
- 2. 强电磁工程与新技术国家重点实验室 华中科技大学电气与电子工程学院,武汉430074
- 3. 湖北省电力勘测设计院,武汉430040
- 折叠
摘要
Abstract
Based on analysis of the dynamic process of the arm capacitors during start-up and DC fault of a MMC,an improved equiv-alent electro-magnetic simulation model of MMC is proposed in this paper,and according to the dynamic characteristics of the total ca-pacitor voltage of an arm,an averaged value model of MMC for its operating condition simulaton is proposed. Then detailed switc-hing,equivalent and averaged value electro-magnetic models of a 21-level MMC are built on PSCAD/EMTDC. By taking simulations during start-up,current step,AC fault and DC fault,the proposd equivalent model and average value model are proved to be suitable to replace the detailed simulation model of MMC in the converter-level study and power system level study with significantly increased simulation speed.关键词
电压源型换流器/模块化多电平换流器/电磁暂态仿真/等值模型/平均值模型Key words
voltage source converter (VSC)/modular multilevel converter (MMC)/electromagnetic simulation/equivalent model/averaged value model分类
信息技术与安全科学引用本文复制引用
蒋霖,周诗嘉,李子寿,向往,胡济洲,程杰,劲宇..可仿真任意工况的MMC等值电磁暂态仿真模型与平均值模型[J].南方电网技术,2016,10(2):10-17,8.