分幅变像管动态空间分辨率的标定∗

袁铮 刘慎业 杨家敏 江少恩 董建军 李晋 陈韬 张文海 曹柱荣 杨志文 王静 赵阳

物理学报2016,Vol.65Issue(9):095202-0-095202-7,8.
物理学报2016,Vol.65Issue(9):095202-0-095202-7,8.DOI:10.7498/aps.65.095202

分幅变像管动态空间分辨率的标定∗

Calibration of the dynamic spatial resolution of framing image-converter

袁铮 1刘慎业 1杨家敏 1江少恩 1董建军 1李晋 1陈韬 1张文海 1曹柱荣 1杨志文 1王静 1赵阳1

作者信息

  • 1. 中国工程物理研究院激光聚变研究中心,绵阳 621900
  • 折叠

摘要

Abstract

In order to improve the two-dimensional imaging diagnostic accuracy of inertial confinement fusion (ICF) exper-iment, a calibration method of the dynamic spatial resolution of X-ray framing image-converter (XFIC) is proposed. When an object with straight edge function is projected onto the photocathode of XFIC as an input, edge spread function can be obtained by recording an image of the XFIC output. The first derivative of the edge spread function produces the line spread function (LSF). Then the modulation transfer function (MTF) of the system can be worked out by Fourier transform of the LSF. Therefore, the spatial resolution can be deduced. According to this theory, the spatial resolution of XFIC can be obtained. Based on SG-II laser facility, the calibrating X-ray source is generated by 8 bundled lasers bombarding the target. High-Z knife-edge is irradiated by the X-ray and imaged on the photocathode of XFIC, and then a dynamic image is obtained as the system works in the gating mode. By handling the dynamic image, the LSF of XFIC is given by analyzing the edge image. Then the MTF of the camera can be indicated by the Fourier transform of the LSF. When the MTF is 0.1, the corresponding spatial resolution of the imaging system is 20 lp/mm. According to the dynamic spatial resolution theory of framing image-converter, the extreme spatial resolution is 22.8 lp/mm. The calibration result agrees with the theoretical results. By contrast, the static spatial resolution of the same X-ray framing image-converter calibrated by the traditional method is presented here. The calibrated static spatial resolution is 22 lp/mm, a little higher than the dynamic one. During the two-dimensional imaging diagnosis, the X-ray framing image-converter works in the dynamic gating mode, thus the calibrated dynamic spatial resolution can be more truthful to reflect its imaging diagnosis ability.

关键词

分幅变像管/动态空间分辨率/调制传递函数

Key words

framing image-converter/dynamic spatial resolution/modulation transfer function

引用本文复制引用

袁铮,刘慎业,杨家敏,江少恩,董建军,李晋,陈韬,张文海,曹柱荣,杨志文,王静,赵阳..分幅变像管动态空间分辨率的标定∗[J].物理学报,2016,65(9):095202-0-095202-7,8.

基金项目

中国工程物理研究院科学技术发展基金(批准号:2014B0102010)资助的课题 (批准号:2014B0102010)

物理学报

OA北大核心CSCDCSTPCDSCI

1000-3290

访问量0
|
下载量0
段落导航相关论文