Abstract
In allusion to the problem that there are no relevant rules or regulations about test items and its evaluation stand-ards for replacing stator bar on the scene for the generator in domestic at present,this paper introduces test items of replace-ment of stator bar on the scene and relevant methods and technical requirements by taking one project of replacing overall bar of stator winding of 600 MW internal water cooling steam turbine generator of some power plant for an example. It presents solutions to problems in the process of replacing the bar which are useful to greatly improve running state of the o-verall unit and its service life.关键词
水内冷发电机/定子绕组线棒/整体更换/试验项目Key words
internal water cooling generator/stator winding bar/overall replacement/test item分类
信息技术与安全科学引用本文复制引用
李浩良,冉旺..水内冷发电机定子线棒整体更换及其试验探讨[J].广东电力,2016,29(5):20-25,6.