局部耦合双回输电线路故障分析计算方法
Analysis and Calculation Method for Fault of Partial Coupling Double-circuit Power Transmission Lines
摘要
Abstract
Existing fault analysis method for double-circuit power transmission lines on the same tower is not applicable any more due to influence of mutual inductance among coupling lines. Therefore,this paper studies fault analysis on partial cou-pling double-circuit power transmission lines. According to structures and characteristics of partial coupling double-circuit transmission lines,sector equations for partial coupling double-circuit power transmission lines are established by using phase component method and port network theory. A kind of fault calculation method for partial coupling double-circuit power transmission lines is realized by combining fault boundary condition equation. Finally,electromagnetic transient simulation software ATP-EMTP is used for constructing a model for emulation proof and the result indicates that the proposed method has small errors in calculation and is not affected by transition resistance and fault types.关键词
局部耦合/同塔双回输电线路/故障分析/相分量法/端口网络理论Key words
partial coupling/double-circuit power transmission line on the same tower/fault analysis/phase component method/port network theory分类
信息技术与安全科学引用本文复制引用
王维航,杜婉琳,梁远升..局部耦合双回输电线路故障分析计算方法[J].广东电力,2016,29(5):97-101,107,6.基金项目
国家自然科学基金项目(51307065) (51307065)