Abstract

There are many capacitive and inductive components in converter station for±800kV DCpower transmission system, which is easy to cause overvoltage phenomenon when a short circuit fault occurred.Research on the characteristics of overvoltage under various operation and fault conditions to ensure the system's safe and stable operation is very important. A simulation model of the UHVDC power transmission project from Yunnan to Guangdong is built by using PSCAD software. To carry out thisresearch, two typical faults in convertstation are chosen:the short circuit fault between the top of convert valve and neutral bus, and single-phase ground fault occurred at the side of converter transformer. Research results show that higher overvoltage appears on the non-faulty pole when short circuit fault between the top of convert valve and neutral bus; among four upper rectifier bridge side of connected winding of convert transformer, the highest overvoltageappears at upper rectifier bridge side wye-wye connected winding of convert transformer when single-phase ground fault occurred.

关键词

特高压直流输电/换流站/避雷器/短路故障/过电压

Key words

UHVDC power transmission/converter station/arrester/short circuit fault/overvoltage