电力系统自动化2016,Vol.40Issue(12):184-188,5.DOI:10.7500/AEPS20150713011
考虑总体误差下降指标的电网参数辨识方法
Network Parameter Identification Method Considering Gross Error Reduction Index
摘要
Abstract
Network parameter errors are important factors influencing the accuracy of state estimation results.Based on weighted least square state estimation,the influence of bad data and error parameter set on gross error is analyzed and the successive identification method of network parameter and measurement errors based on gross error reduction index is proposed.Along with the ability to identify multiple network parameter and measurement errors simultaneously,this method is equivalent to the normalized Lagrange multiplier method for a single parameter or measurement error identification.The identification results of IEEE 14-bus test system verify the accuracy and superiority of the proposed identification method.关键词
参数辨识/不良数据辨识/总体误差/正则化拉格朗日乘子法/状态估计Key words
parameter identification/bad data identification/gross error/normalized Lagrange multiplier method/state estimation引用本文复制引用
侯方迪,朱涛,赵川,叶华,吴涛,郭瑞鹏..考虑总体误差下降指标的电网参数辨识方法[J].电力系统自动化,2016,40(12):184-188,5.基金项目
国家高技术研究发展计划(863计划)资助项目(2011AA05A118)。@@@@This work is supported by National High Technology Research and Development Program of China (863 Program)(No.2011AA05A118) (863计划)