| 注册
首页|期刊导航|中国医学创新|化学发光微粒子免疫法与电化学发光法测定促甲状腺激素的性能比较

化学发光微粒子免疫法与电化学发光法测定促甲状腺激素的性能比较

范婵 陈姝 龚国忠

中国医学创新2016,Vol.13Issue(18):61-64,4.
中国医学创新2016,Vol.13Issue(18):61-64,4.DOI:10.3969/j.issn.1674-4985.2016.18.018

化学发光微粒子免疫法与电化学发光法测定促甲状腺激素的性能比较

Performance of Thyroid Stimulating Hormone by Chemiluminescence Particles Immune Method and Electrochemical Luminescence

范婵 1陈姝 1龚国忠1

作者信息

  • 1. 四川省遂宁市中心医院 四川 遂宁 629000
  • 折叠

摘要

Abstract

Objective:To compare the performance of serum thyroid stimulating hormone by chemiluminescence particles immune method (CMIA) and electrochemical luminescence (ECLINA).Method:Eight clinical samples was selected every day,including outpatient and inpatient,exclusion of hemolysis,blood lipid and medication situation,continuous determination of 7 d and the test results was recorded.The outliers was removed,the ECLINA was used as the contrast method for X axis and the CMIA was used as the experimental method for Y axis,the linear equation and correlation coefficient of CMIA and ECLINA were calculated for evaluation bias.Result:CMIA and ECLINA to determine the linear regression equation for thyroid stimulating hormone was Y=0.7863X+0.0632, correlation coefficient wasr2=0.9946,There was a high correlation with the measured values of two methods.The two kinds of detection method of measured value were highly correlated (P<0.01).Two kinds of experimental methods all existed along with the increase of the results,but could meet the clinical requirements.Conclusion:CMIA and ECLINA is highly correlated,correlation equation can be established,in a certain way can not meet the laboratory and the reference value can not be replaced by another way.

关键词

化学发光微粒子免疫法/电化学发光法/性能

Key words

Chemiluminescence particles immune method/Electrochemical luminescence/Performance

引用本文复制引用

范婵,陈姝,龚国忠..化学发光微粒子免疫法与电化学发光法测定促甲状腺激素的性能比较[J].中国医学创新,2016,13(18):61-64,4.

中国医学创新

1674-4985

访问量0
|
下载量0
段落导航相关论文