移动通信2016,Vol.40Issue(9):89-92,4.DOI:10.3969/j.issn.1006-1010.2016.09.017
处置光缆割接所引发SDH(STM-64)误码的浅谈
Brief Discussion on Dealing the STM-64 Level SDH Error Code Caused by Cutting and Connecting Fiber Optic Cable
余林立1
作者信息
- 1. 福州大学物理与信息工程学院,福建 福州 350116
- 折叠
摘要
Abstract
Through checking and researching on the error code alarm of 10G SDH optic-transfer equipment caused by cutting and connecting ifber optic, and studying and analyzing the performance index of Metro 5000 (HUAWEI) equipment’s SL64 plate, the results are combined and summarized. The generation mechanism of RSBBE, RSES, MSBBE, MSES in the optic-ifber link was discussed. The paper explicated how daily cutting and connecting of optic ifber cable can cause error code of optic-link, including how to solve the problem and how to think, providing reference for checking, locating and making resolution to remove this type of optic transfer fault.关键词
光缆线路/SDH/误码/再生段/复用段Key words
optic ifber/SDH/error code/regenerator section/multiplex section分类
信息技术与安全科学引用本文复制引用
余林立..处置光缆割接所引发SDH(STM-64)误码的浅谈[J].移动通信,2016,40(9):89-92,4.