Abstract
The water-ingress accident resulted from a double-ended guillotine break of two steam generator heating tubes is a typical beyond design basis accident of HTR-PM w hich may cause the aggregation of hydrogen in the cavity ,and consequently result in the threat of deflagration or even detonation .The paper simulated the behavior of gas entering the cavity after the double-ended guillotine break of two heating tubes ,using the GASFLOW program .Besides ,COM3D program was used to analyze the combus-tion of hydrogen in the cavity .According to the simulation results ,the concentration of hydrogen in the containment is quite small ,and the maximum value is below 0.1% , which means that there will exist no risk of hydrogen explosion in the HTR-PM when the water-ingress accident happens .关键词
模块式高温气冷堆/进水事故/两根传热管断裂/氢气分布Key words
HTR-PM/water-ingress accident/double-ended guillotine break of two heating tubes/hydrogen distribution分类
能源科技引用本文复制引用
张睿东,孙喜明,董玉杰..模块式高温气冷堆进水事故后的氢气行为分析[J].原子能科学技术,2016,50(5):841-845,5.基金项目
国家科技重大专项资助项目(ZX06901) (ZX06901)