硬膜外置管长度对剖宫产麻醉效果的影响分析

徐艳伟

中国社区医师2016,Vol.32Issue(15):72-73,2.
中国社区医师2016,Vol.32Issue(15):72-73,2.DOI:10.3969/j.issn.1007-614x.2016.15.40

硬膜外置管长度对剖宫产麻醉效果的影响分析

Effect analysis of length of epidural tube on the anesthetic effect in cesarean section

徐艳伟1

作者信息

  • 1. 550005贵州省第三人民医院
  • 折叠

摘要

Abstract

Objective:To investigate the effects of length of epidural tube on the anesthetic effect in cesarean section. Methods:260 cases of puerpera with cesarean section were divided into two groups randomly,with 130 cases in each group.The control group was given anesthesia with 3 cm length of epidural tube,and the observation group was given anesthesia with 5 cm length of epidural tube.The anesthetic effect of the two groups was compared.Results:There were no statistically signiifcant differences of mean arterial pressure,heart rate and blood oxygen saturation between after anesthesia and before anesthesia (P>0.05).The total anesthetic satisfaction of the observation group was 95.4%,which was signiifcantly higher than that of the control group(P<0.05).The utilization rate of supplementary medicines in the observation group was signiifcantly lower than that in the control group,and the difference was statistically signiifcant(P<0.01).Conclusion:The length of epidural tube had signiifcant influence on the anesthetic effect in cesarean section.

关键词

硬膜外置管长度/剖宫产/麻醉效果

Key words

Length of epidural tube/Cesarean section/Anesthetic effect