Abstract
The failure of blow‐off actuator will make compressor produce strong surging and vibration , resulting in serious problems to unit safety .So gas turbine is required to have strict reliability and quick response on the blow‐off pneumatic control system .Accordingly ,the design reliability of existing system was calculated and optimized based on analysis on principle of blow‐off pneumatic control system module , afterwards ,the optimized design was tested and validated to provide a better effective ,reliable and safe blow‐off pneumatic control system to customers .关键词
燃气轮机/放风/可靠性Key words
gas turbine/blow-off/reliability分类
能源科技引用本文复制引用
张帅,唐健,严晶..燃气轮机防喘放风气系统可靠性分析与优化[J].热力透平,2016,45(1):70-74,5.