云南化工2016,Vol.43Issue(3):36-38,3.DOI:10.3969/j.issn.1004-275X.2016.03.010
氢化物发生-原子荧光光谱法测定载金炭中砷
Determination of Arsenic Content in Gold -loaded Carbon by Hydride Generation -atomic Fluorescence Spectrometry
李华荣1
作者信息
- 1. 福建紫金矿冶测试技术有限公司,福建 上杭 364200
- 折叠
摘要
Abstract
The gold -loaded carbon samples were dissolved by the nitric acid and sulfuric acid.Car-bon base were removed through the smoke.The arsenic content was determined by the AFS with thiourea -acsorbic acid which turned the AS(5 +)to the AS(3 +).The detection limit of the method was 0.093 g/L, and the relative standard deviations of 5 different amounts of samples were between 1 .59% and 5.52%,the recoveries were in the range of 96% to 1 01 %.关键词
氢化物发生-原子荧光光谱法/载金炭/砷Key words
hydride generation/atomic fluorescence spectrometry/gold -loaded carbon/arsenic分类
化学引用本文复制引用