摘要

Abstract

In allusion to status quo of high NOx emission concentration of No.2 boiler in one power plant,transformation on selective catalytic reduction (SCR)denitration system is conducted. Due to uneven distribution of NOx concentration at the outlet of reactor after denitration transformation which causes vast ammonia escape and low denitrationefficiency,adjust-ment experiment on ammonia injection grid of the denitration system and performance evaluation after the transformation are both carried out. The main conclusion is summarized as follows that the adjustment experiment on ammonia injection grid gets effect and it is necessary to conduct adjustment experiment on ammonia injection grid regularly so as to prevent air pre-heater blocked caused for reason of vast ammonia escape at the outlet. In addition,under the premise of satisfying re-quirement for environment protection,it should not pursue higher denitration efficiency and consequently reduce denitration cost and risk of causing vast ammonia escape.

关键词

选择性催化还原/喷氨格栅/优化调整/氨逃逸

Key words

selective catalytic reduction (SCR)/ammonia injection grid/optimization adjustment/ammonia escape

分类

动力与电气工程

引用本文复制引用

李德波,廖永进,曾庭华,邓剑华,许凯,李方勇..SCR 脱硝系统喷氨格栅调整试验关键问题探究[J].广东电力,2016,29(7):11-15,5.

基金项目

国家自然科学基金项目(51376161) (51376161)

广东电力

OACSTPCD

1007-290X

访问量0
|
下载量0
段落导航相关论文