| 注册
首页|期刊导航|广东电力|非理想电压时一种改进的 ip-iq 检测法

非理想电压时一种改进的 ip-iq 检测法

吴超

广东电力2016,Vol.29Issue(7):72-77,6.
广东电力2016,Vol.29Issue(7):72-77,6.DOI:10.3969/j.issn.1007-290X.2016.07.014

非理想电压时一种改进的 ip-iq 检测法

An Improved ip-iq Detection Method Under the Condition of Non-ideal Voltage

吴超1

作者信息

  • 1. 国网浙江省电力公司湖州供电公司,浙江 湖州313000
  • 折叠

摘要

Abstract

There are some errors in detecting compensation command current by traditional ip-iq method under the condition of non-ideal voltage and conversion of current computing coordinate is complicated. In allusion to these problems,this paper presents a kind of improved ip-iq method suitable for non-ideal grid voltage on the basis of analyzing traditional ip-iq meth-od. This method uses sine and cosine information to extract module to replace phase-locked loop so as to correctly extract phase information of fundamental positive sequence voltage,remove impact of phase-locked loop on detection and reduce coordinate conversion and filter delay in current computation. Simulating analysis and experimental verification is conducted in MATLAB/Simulink software and distribution static synchronous compensator (D-STATCOM)prototype and results prove effectiveness and feasibility of the proposed method.

关键词

配电网静止同步补偿器/ip-iq 法/非理想电网电压/基波正序电压

Key words

distribution static synchronous compensator(D-STATCOM)/ip-iq method/non-ideal grid voltage/fundamental positive sequence voltage

分类

信息技术与安全科学

引用本文复制引用

吴超..非理想电压时一种改进的 ip-iq 检测法[J].广东电力,2016,29(7):72-77,6.

广东电力

OACSTPCD

1007-290X

访问量0
|
下载量0
段落导航相关论文