| 注册
首页|期刊导航|中国比较医学杂志|发光二极管光源照射日本大耳白兔皮肤的安全性评价

发光二极管光源照射日本大耳白兔皮肤的安全性评价

李彦红 秦川 张继刚 徐艳峰 韩云林 黄澜 江彬彬 朱华 徐玉环 杨维玲

中国比较医学杂志2016,Vol.26Issue(7):24-30,7.
中国比较医学杂志2016,Vol.26Issue(7):24-30,7.DOI:10.3969.j.issn.1671-7856.2016.07.004

发光二极管光源照射日本大耳白兔皮肤的安全性评价

The safety assessment on the light emitting diode (LED) resource through irradiating the skin of Japanese big-ear white rabbits

李彦红 1秦川 1张继刚 2徐艳峰 1韩云林 1黄澜 1江彬彬 2朱华 1徐玉环 1杨维玲2

作者信息

  • 1. 中国医学科学院,北京协和医学院,医学实验动物研究所,卫生部人类疾病比较医学重点实验室,国家中医药管理局人类疾病动物模型三级实验室,新发再发传染病动物模型研究北京市重点实验室,北京 100021
  • 2. 中国人民解放军火箭军总医院,北京 100088
  • 折叠

摘要

Abstract

Objective To evaluate the safety of Light emitting diode ( LED) source through irradiating the skin of Japanese big⁃ear white rabbits. Methods Animals were randomly divided into irradiated group and control group. Animals in the two groups were irradiated with LED light source after eliminating back hair (50mw/cm2 ) and the ordinary fluorescent lamp, respectively. The animals were irradiated for 5 hours every day for 3 months. The changes of animal skin symptoms, feeding, body weight, and temperature were observed and detected;the blood routine and biochemical indexes were tested;the changes of haematological immune cells and cytokines were analyzed by ELISA;histopathology and elastic fibers of skin were detected; the levels of C⁃myc, P53, and cyclin D1 in skin were tested by immunohistochemistry. Results The skin of rabbits in irradiated group showed no abnormal change;the weight was higher than the control group animals at the 6th week, and the temperature had difference at the 3rd and 6th week, the diet showed no abnormal. Blood routine showed white blood cells increased;biochemical detection manifested urea and creatinine levels increased, but the indexes are in normal range;the hematological CD3T cells, cytokines IL⁃6,TNF⁃αand IFN⁃γin the two group animals had no significant difference. The levels of CD19B cell and IL⁃4 level increased in irradiated group;The viscera histopathology structure and skin elastic fibers distribution in irradiated group animals showed normal;the expression of cell cycle protein 1 (CCND1), c⁃myc protein and P53 protein in skin of irradiated group had no difference with control. Conclusions After irradiating 3 months, the LED light source had not caused the obvious pathology damage of tissues and change of skin tumor related factors to the rabbits.

关键词

发光二极管/日本大耳白兔/皮肤/安全评价

Key words

Light emitting diode/Japanese big-ear white rabbit/Skin/Safety assessment

分类

医药卫生

引用本文复制引用

李彦红,秦川,张继刚,徐艳峰,韩云林,黄澜,江彬彬,朱华,徐玉环,杨维玲..发光二极管光源照射日本大耳白兔皮肤的安全性评价[J].中国比较医学杂志,2016,26(7):24-30,7.

基金项目

十二五重大科技专项(2012ZX10004-501);国家高技术研究发展计划(863计划)课题子任务(2003AA123310)。 ()

中国比较医学杂志

OA北大核心CSTPCD

1671-7856

访问量0
|
下载量0
段落导航相关论文