| 注册
首页|期刊导航|强激光与粒子束|溴化镧高剂量率线性响应范围的测定

溴化镧高剂量率线性响应范围的测定

易义成 宋朝晖 管兴胤 李刚

强激光与粒子束2016,Vol.28Issue(9):096002-1-096002-5,5.
强激光与粒子束2016,Vol.28Issue(9):096002-1-096002-5,5.DOI:10.11884/HPLPB201628.151241

溴化镧高剂量率线性响应范围的测定

Measurement of linear response upper limit for LaBr3 to pulsed gamma radiation

易义成 1宋朝晖 1管兴胤 2李刚1

作者信息

  • 1. 西北核技术研究所,西安 710024
  • 2. 强脉冲辐射环境模拟与效应国家重点实验室,西安 710024
  • 折叠

摘要

Abstract

Scintillation detectors based on LaBr3 are the new type of detectors for measuring γ-rays in a mixed γ/n pulsed radiation field with high intensity.It owns superior properties such as fast response time,small nonproportionality,and high scintillation yield.As the fluence rate linear response limit of LaBr3 scintillator is not available in literature,an experiment which studies the high fluence rate response behavior of LaBr3 scintillators is introduced in this paper.Lissajous figure method is used in the experiment.The result shows that the fluence rate linear response limit is about 2.0×10 1 8 MeV/(cm2 ·s).

关键词

溴化镧/剂量率/线性响应/李萨如图形

Key words

LaBr3 scintillator/fluence rate/linear response limit/Lissajous figure

分类

能源科技

引用本文复制引用

易义成,宋朝晖,管兴胤,李刚..溴化镧高剂量率线性响应范围的测定[J].强激光与粒子束,2016,28(9):096002-1-096002-5,5.

基金项目

国家自然科学基金项目(1157146,11205122) (1157146,11205122)