| 注册
首页|期刊导航|照明工程学报|广州某地铁站LED节能改造后一般照明质量评价实例

广州某地铁站LED节能改造后一般照明质量评价实例

赵浩之 刘菊 王深 蒋春旭

照明工程学报2016,Vol.27Issue(4):47-51,5.
照明工程学报2016,Vol.27Issue(4):47-51,5.DOI:10.3969∕j.issn.1004-440X.2016.04.008

广州某地铁站LED节能改造后一般照明质量评价实例

Quality Evaluation Method for LED Lighting Renovation Project of Subway Stations in Guangzhou

赵浩之 1刘菊 1王深 1蒋春旭1

作者信息

  • 1. 工业和信息化部电子第五研究所,广东 广州 510610
  • 折叠

摘要

Abstract

In this paper, according to the standards Measurement Methods for Lighting, Urban Rail Transit Lighting and Technical Specification for LED Lamps Used for Lighting in Subway Station, a subway station in Guangzhou was evaluated on the LED lighting renovation project quality. In combination with the actual situation of the subway station, the illumination and uniformity, color and color rendering, glare and energy saving and other indicators were tested. A more detailed evaluation method for the quality of subway station lighting is summarized.

关键词

地铁站/LED照明/照度/眩光/节能

Key words

subway station/LED lighting/illumination/glare/energy saving

分类

信息技术与安全科学

引用本文复制引用

赵浩之,刘菊,王深,蒋春旭..广州某地铁站LED节能改造后一般照明质量评价实例[J].照明工程学报,2016,27(4):47-51,5.

照明工程学报

OACSTPCD

1004-440X

访问量0
|
下载量0
段落导航相关论文