南方电网技术2016,Vol.10Issue(7):17-23,7.DOI:10.13648/j.cnki.issn1674-0629.2016.07.004
异步联网后云南电网的频率特性及高频切机方案
Frequency Characteristics of Yunnan Power Grid and Corresponding Over-Frequency Generator Tripping Scheme After Asynchronous Interconnection
周磊 1张丹 2刘福锁 1黄伟 2李威 1吴琛2
作者信息
- 1. 国电南瑞科技股份有限公司,南京211100
- 2. 云南电力调度控制中心,昆明650011
- 折叠
摘要
Abstract
Frequency stability will become the main security risk of Yunnan Power Grid as multi-DC sending end with small load and large sending-power after the asynchronous interconnection with CSG. The influences of load model and governor parameters on fre-quency characteristics are investgated. The principle of coordination and optimization of over-requency generator tripping are proposed. Based on the simulation and analysis of 4 alternative schemes,the over-frequency generator tripping scheme is proposed for Yunnan Power Grid to meet the requirements of asynchronous interconnection.关键词
异步联网/多回直流闭锁/频率特性/高频切机Key words
asynchronous interconnection/multi-DC blocking/frequency characteristic/over-frequency generator tripping分类
信息技术与安全科学引用本文复制引用