| 注册
首页|期刊导航|激光技术|基于荧光微球的显微镜点扩散函数修正模型

基于荧光微球的显微镜点扩散函数修正模型

鹿伟民 杨西斌 文刚 郑贤良 李辉 熊大曦

激光技术2016,Vol.40Issue(5):638-642,5.
激光技术2016,Vol.40Issue(5):638-642,5.DOI:10.7510/jgjs.issn.1001-3806.2016.05.005

基于荧光微球的显微镜点扩散函数修正模型

An optimized model of point spread function of microscopy based on fluorescence beads

鹿伟民 1杨西斌 2文刚 3郑贤良 1李辉 1熊大曦1

作者信息

  • 1. 中国科学院苏州生物医学工程技术研究所江苏省医用光学重点实验室,苏州215163
  • 2. 中国科学院长春光学精密机械与物理研究所,长春130033
  • 3. 中国科学院大学材料科学与光电技术学院,北京100039
  • 折叠

摘要

Abstract

In order to eliminate effect of fluorescent bead diameter on measurement results in traditional microscopic point spread function measurement method and improve the measurement accuracy , 2-D equivalent concentration distribution of fluorescent beads was deduced based on theoretical simulation and least square fitting method .The imaging process of fluorescent beads was simulated .The relationships among fluorescent beads diameter , full width at half maximum ( FWHM) of fluorescent beads intensity distribution and FWHM of system point spread function were analyzed by using the least square fitting method and residual error fitting method .Precise FWHM correction model of point spread function was obtained .The results show that the relative error of point spread function FWHM is about 1%when measuring system point spread function with 100nm fluorescent beads.The precise measurement of point spread function is realizable with the optimized model .

关键词

显微/点扩散函数/荧光微球/非线性最小二乘拟合

Key words

microscopy/point spread function/fluorescent bead/nonlinear least square fitting

分类

数理科学

引用本文复制引用

鹿伟民,杨西斌,文刚,郑贤良,李辉,熊大曦..基于荧光微球的显微镜点扩散函数修正模型[J].激光技术,2016,40(5):638-642,5.

基金项目

国家自然科学基金资助项目(61475185);国家自然科学基金青年科学基金资助项目(61405238);中国科学院百人计划资助项目 ()

激光技术

OA北大核心CSCDCSTPCD

1001-3806

访问量0
|
下载量0
段落导航相关论文