内蒙古电力技术2016,Vol.34Issue(4):78-80,85,4.DOI:10.3969/j.issn.1008-6218.2016.04.002
SCR烟气脱硝系统喷氨优化实例分析
Example Analysis of SCR System Spraying Ammonia Optimization
赵宇 1那钦1
作者信息
- 1. 内蒙古电力科学研究院,呼和浩特 010020
- 折叠
摘要
Abstract
One power plant did not increase the third layer of NOx catalyst, just trying to increase the amount of ammonia spray, to reduce the NOx concentration, which caused that NOx concentration appearing serious deviation. The CEMS monitoring data, between SCR flue outlet NOx concentration and the chimney inlet of NOx concentration, showed that there was serious difference of 30 mg/m3. Based on the practical experience, this paper introduced how to improve the uniformity of NOx and NH3 by optimizing the operation mode, and to eliminate the deviation of NOx concentration. Experience could be used for the same type of unit.关键词
SCR烟气脱硝系统/NOx质量浓度/喷氨量/均匀度/阀门优化Key words
SCR flue gas denitrification system/NOx mass concentration/spray amount of ammonia/uniformity/valve optimization分类
资源环境引用本文复制引用
赵宇,那钦..SCR烟气脱硝系统喷氨优化实例分析[J].内蒙古电力技术,2016,34(4):78-80,85,4.