Abstract

When the once-through boiler of 350 MW supercritical unit is started, high water quality requirements is asked for in Hohhot Thermal Power Plant, so high water consumption exists during the rinse under cold and hot condition, processing temperature is low, and in addition desaltign salt water tank water level is low, it can′t meet the requirements of boiler normal boot. Optimization measures such as high desalting water level in water tank was taken before unit start-up. The optimized dosage of boiler flushing method saves desalting water, and shortens the time of washing, the effect is good.

关键词

350 MW超临界直流锅炉/热态冲洗/冷态冲洗/除盐水

Key words

350 MW supercritical once-through boiler/hot state washing/cool state washing/desalting water